Back to Procedures
1070

Waveform Capnography

Updated Updated November 2026. What changed: EtCO2 targets for brain injury were raised: 35-45 mmHg for TBI (was 32-35 mmHg for head injury/stroke) and 30-35 mmHg for herniation (was 25-30 mmHg). Capnography indications now read "should have" rather than "mandatory", add respiratory distress/failure and cardiac arrest, and drop sepsis; chronic CO2 retainer guidance now gives targets of SpO2 88-92%, Vt 6-8 mL/kg, low-normal RR and adequate expiratory time.
These protocols are here as an example, and are not to be used as an official resource or for patient care.

Indications:

  • To verify endotracheal tube placement
  • Patients with the following should have ETCO2 monitoring:
    • Mechanical ventilation / endotracheal intubation
    • Shock
    • Respiratory distress or failure
    • Cardiac arrest
    • Altered mental status
    • OB patients on magnesium
    • Any patient receiving narcotics or sedatives

Contraindications: None

Technique:

  • Normal range EtCO2 value 35-45mmHg
  • Patients without ETT (Endotracheal Tube) or advanced airway in place: place ETCO2 detector in-line between ambu bag and face mask
  • In a patient with ETT or advanced airway: place ETCO2 detector in-line between airway adapter and BVM (Bag Valve Mask) after airway is positioned and secured
  • Patients without ETT or advanced airway in place: place ETCO2 cannula on patient. May be placed under CPAP (Continuous Positive Airway Pressure) or NRB facemask
  • Assess and document both capnography waveform and ETCO2 value

Precautions:

  • To understand and interpret capnography, remember the 3 determinants of ETCO2:
    1. Alveolar ventilation
    2. Pulmonary perfusion
    3. Metabolism
  • Sudden loss of ETCO2:
    1. Tube dislodged
    2. Circuit disconnected
    3. Cardiac arrest
  • High ETCO2 (> 45):
    1. Hypoventilation/CO2 retention
  • Low ETCO2 (< 25):
    1. Hyperventilation
    2. Low perfusion: shock, PE (Pulmonary Embolism), sepsis
  • Cardiac Arrest:
    1. In low-pulmonary blood flow states, such as cardiac arrest, the primary determinant of ETCO2 is blood flow, so ETCO2 is a good indicator of quality of CPR (Cardiopulmonary Resuscitation)
    2. If ETCO2 is dropping, change out the person doing chest compressions
    3. In cardiac arrest, if EtCO2 is not > 10 mmHg after 20 minutes of good CPR, this reflects exceptionally low CO2 production and is associated with poor outcome
    4. Sudden rise in EtCO2 may be an indicator of ROSC (return of spontaneous circulation)

Considerations:

  • EtCO2 is 3-5 units less than PaCO2 (pressure of arterial CO2). In shock states, this difference is greater, and correlation is unreliable. When in doubt, draw a blood gas if able.
  • In the pregnant patient, ETCO2 may be lower (27-34mmHg) due to respiratory alkalosis and increased respiratory rates.
  • Goal for TBI patients is 35-45 mmHg. If rapid neurologic deterioration with evidence of herniation occurs, target goal 30-35 mmHg as a temporizing measure.
  • Caution must be used to avoid normal levels of ETCO2 in the chronic CO2 retainer. Instead, target low-normal oxygen levels (88-92% SpO2), protective Vt (6-8mL/kg), low-normal RR, and ensure adequate expiratory time.

Normal and abnormal etCO2/capnograph waveforms (Medtronic reference):

Normal capnogram: a waveform which represents the varying CO2 level throughout the breath cycle. Waveform characteristics: A-B baseline, B-C expiratory upstroke, C-D expiratory plateau, D end-tidal concentration, D-E inspiration.

Waveform patternetCO2Other possible causes
Normal capnogram35-45 mmHgNormal waveform throughout the breath cycle
Bronchospasm/Asthma (loss of plateau)> 45 mmHgBronchospasm/COPD; obstruction in the expiratory limb of the breathing circuit; presence of a foreign body in the upper airway; partially kinked or occluded artificial airway
Increasing etCO2 (Hypoventilation)*> 45 mmHgDecrease in respiratory rate; decrease in tidal volume; increase in metabolic rate; rapid rise in body temperature (malignant hyperthermia)
Decreasing etCO2 (Hyperventilation)*< 35 mmHgIncrease in respiratory rate; increase in tidal volume; metabolic acidosis; fall in body temperature
Rebreathing CO2> 45 mmHgFaulty expiratory valve; inadequate inspiratory flow; partial rebreathing; insufficient expiratory time
Curare Cleft35-45 mmHgPatient is mechanically ventilated; depth of cleft is proportional to degree of muscle relaxants
Cardiac ArrestDecreased or absent cardiac output; decreased or absent pulmonary blood flow; sudden decrease in CO2 values
Return of Spontaneous CirculationIncrease in cardiac output; increase in pulmonary blood flow; gradual increase in CO2 production

* Assumes adequate circulation and alveolar gas exchange.