1121
Tourniquet Conversion
These protocols are here as an example, and are not to be used as an official resource or for patient care.
Tourniquet applied PTA (40% applied by non-medical personal).
Definitions:
- Appropriate: A tourniquet deemed necessary to control life threatening hemorrhage per provider judgement
- Effective: Bleeding control at injury site and the absence of a distal pulse
- Conversion: The process of safely loosening a previously placed tourniquet to reduce the risk of limb ischemia and other complications associated with tourniquet use
- Plus-1 tourniquet: A 2nd tourniquet placed proximal to the original tourniquet
Yes to any criteria?
- Is there partial or complete amputation?
- Is patient in shock? (SPB <90 mmHg)
- Will the affected limb be hidden/obscured during transport?
YesDo not convert
NoContinue below
Tourniquet time < 6 hours?
1Do Not Convert
- Ensure that tourniquet is effective
- Do NOT REMOVE tourniquet
2Tourniquet Conversion
- Apply Plus-1 tourniquet and pressure dressing
- Loosen original tourniquet
Pressure dressing recommendations: Apply pressure dressing and hold pressure for approximately 3 min to ensure enough pressure has been applied to properly assess.
Bleeding through dressing?
YesTighten Plus-1, below
NoLeave loosened tourniquets in place - Tighten Plus-1 tourniquet
Tourniquet effective?
YesNote time and leave in place
NoTighten original tourniquet, below
- Tighten original tourniquet
- Note time tightened
- Treat pain per protocol
- CONTACT BASE if needed for consult
3Conversion Not Advised
- Conversion NOT ADVISED
- Ensure tourniquet is effective
4Leave Loosened Tourniquets in Place
- Leave loosened tourniquets in place and reassess as needed
5Note Time and Leave in Place
- Note time and leave in place
- Treat pain per protocol
- CONTACT BASE if needed for consult