Updated Updated November 2026. What changed: Adult needle decompression now prefers the 4th or 5th intercostal space at the anterior midaxillary line (2nd intercostal midclavicular only if the lateral chest is inaccessible or in late-term pregnancy), and a new pediatric section gives age-based landmarks, 16G/22G angiocath sizes and a syringe-and-stopcock aspiration technique. Indications now require hypotension with signs of shock and absent (no longer "or decreased") unilateral breath sounds.
These protocols are here as an example, and are not to be used as an official resource or for patient care.

Indications:

All the following clinical indicators must be present:

  • Severe respiratory distress
  • Hypotension and signs of shock
  • Unilateral absent breath sounds

OR

  • Traumatic pulseless arrest with trauma to the torso

May also see tracheal deviation, distended neck veins, increased resistance to bagging, subcutaneous emphysema, persistent cyanosis

Technique:

Adults:

  • Expose entire chest
  • Identify the insertion site and landmarks, size of angiocath, and clean skin overlying site with available skin prep
    • 4th or 5th intercostal space in the anterior midaxillary line is the preferred location in adults
    • 2nd intercostal space at midclavicular line is appropriate if you are unable to access the lateral chest wall or in late-term pregnant patients.
  • For adults, use the largest, longest available angiocath (ex., 14 G x 3.25” ARS). Insert the needle at the top margin of the rib to avoid the neurovascular bundle that travels along the lower margin of the rib. Advance until you are through the pleura, then hold the needle steady and thread the catheter into the chest. Withdraw the needle. Notify the receiving hospital of needle decompression attempt

Pediatrics:

  • Landmarks
    • ≥ 6 months - <12 YO: 4th or 5th intercostal space anterior midaxillary line, or the 2nd intercostal space in the midclavicular line
    • Preferred approach is the anterior midaxillary line. If the anterior midaxillary is difficult to access, midclavicular is acceptable.
    • < 6 months: 2nd intercostal space in the midclavicular line
  • Angiocath Size
    • ≥ 6 Months (Red on HT)- < 12 years old- 16G angiocath
    • < 6 Months (Gray or Pink on HT)- 22G angiocath
  • Technique:
    • Prepare equipment needed for needle decompression based on patient size (found in decompression kit)
    • Assemble premade system:
    • Attach stopcock to 20cc syringe with the stopcock turned off to the atmosphere
    • Take 10cc NSS flush, expel 5cc of NSS
    • Attach NSS flush to angiocath
    • Expose patient’s chest and identify landmark
    • Clean landmark site with iodine or alcohol prep (iodine preferred)
    • Confirm landmark
    • Keep index finger of non-dominant hand on rib below the intercostal space (to maintain your landmark)
    • Carefully insert the angiocath over the top of the rib, stopping once you puncture the pleura
    • Pull back on the NS syringe until bubbles are visualized
    • Advance the catheter into the chest while holding the needle in place
    • While holding the catheter with the non-dominant hand, attach a premade system to the catheter.
    • Withdraw air until resistance is met or syringe is full. If syringe is full, turn stopcock off to patient and expel air to atmosphere. Repeat process until resistance is met
    • Once resistance is met, remove catheter completely from patient and cover site with gauze

Notify receiving hospital of decompression attempt

Precautions:

  • If the angiocath becomes occluded with blood or soft tissue or if the patient has returning symptoms, consider repeating this procedure.
  • A simple pneumothorax is NOT an indication for needle decompression.

Considerations:

Charting requirements:

  • Site cleansed.
  • Size of catheter, site, laterality
  • Number of attempts
  • Results (improvement in condition, bubbling of blood or release of air, etc.)