Introduction:
- Needle cricothyrotomy is a difficult procedure that is to be used only in extraordinary circumstances as defined below.
- The reason for performing this procedure must be documented and submitted for review to the LifeLine Medical Director within 24 hours of the call.
See also: Needle Cricothyrotomy tool.
Indications:
- Patients <12 years when complete or near-complete upper airway obstruction is suspected from a medical or traumatic cause
- A life-threatening condition exists AND advanced airway management is indicated, AND adequate oxygenation and ventilation cannot be accomplished by other less invasive means; unable to oxygenate/ventilate with BLS (Basic Life Support) measures, i-Gel or other supraglottic airway, and endotracheal intubation.
- Temporary airway for when other methods have been unsuccessful.
Procedure:
- Have all equipment ready and within reach prior to starting. 3.0 ETT (Endotracheal Tube) adaptor, 10-14g needle depending on size of patient, 10ml syringe.
- Don appropriate BSI/PPE.
- Identify and cleanse the cricothyroid membrane.
- Choose needle gauge to be the largest size safely able to pass through the cricothyroid cartilage (10g-14g most common sizes). Position the IV catheter at a 90-degree angle to the neck
- Pierce the skin and insert the catheter tip into the center of the cricothyroid membrane at a 30-degree angle, aimed caudally
- Advance slowly until the needle tip enters the trachea, advancing 2-5 mm more to ensure correct entry. Retract the needle and attach the syringe; try to withdraw air to confirm tracheal placement
- Attach the connector from a 3.0 ET tube to that of the hub of the catheter and attach the BVM (Bag Valve Mask)
- Check for bilateral breath sounds, and check EtCO2 waveform. Understand that exaggerated resistance to manual bagging will be normal due to the small lumen of the catheter
- Ventilate the patient at a ratio of one breath every 5 seconds. Allow for adequate exhalation.
- Hold the catheter manually and observe for subcutaneous air infiltration
- Upon confirming EtCO2 waveform and breath sounds bilaterally, with no signs of subcutaneous air infiltration, secure in place
- Provide continuous reassessment of the patient
Complications:
- Insertion in subcutaneous tissue or right mainstem if catheter is advanced too deep.
- Injury to thyroid, vessels, larynx, and vocal cords if landmarks are not well identified.
Consideration:
- The addition of 2 mL of NS (Normal Saline) in the syringe attached to the IV catheter may aid in visual confirmation during air aspiration, as you will be able to see bubbles.
- Using an IV extension between the catheter and 3.0 ET tube connector will aid in securing the catheter and reduce the chance of kinking or displacement of the catheter.
- EtCO2 waveform may be lower in amplitude or absent due to a smaller catheter size
- This form of airway management is only temporary and provides excellent oxygenation but poor ventilation, thereby causing dangerous hypercarbia after 30-45 minutes.
- Allow the patient to exhale through the glottic opening rather than the needle catheter.