Maintenance of Esophagogastric Tamponade Tube
Introduction:
Esophagogastric tamponade tubes are a temporizing measure used in catastrophic upper gastrointestinal hemorrhage. Most often, these esophageal variceal bleeds require interventional radiology to clip, coil, embolize, perform a TIPS (Transjugular Intrahepatic Portosystemic Shunt) procedure, or undergo open surgery. Placing this tube is a rescue maneuver, and it should be in place no longer than 24 hours to avoid tissue necrosis of surrounding structures.
Indications:
- Life-threatening upper gastrointestinal hemorrhage unresponsive to medical and endoscopic treatment
Contraindications:
- Non-intubated patients
- Patients with a latex allergy, as all esophagogastric tamponade tubes contain latex
- Known esophageal stricture or recent gastric surgery
Considerations:
This tube should be in place prior to the transport team's departure from the sending facility. The transport team is not to initiate placement, though may be present, assist the provider as asked and within scope of practice, and team comfort level.
Source page is a figure: a labeled drawing of a Minnesota tube ("Pictured is a Minnesota Tube") showing the gastric balloon port, gastric aspiration port, esophageal balloon port, esophageal aspiration port, length marks, esophageal aspiration opening, esophageal balloon, gastric balloon and gastric aspiration openings.
There are several types of tamponade balloon catheters, each with slight differences.
- Sengstaken-Blakemore tubes have a gastric balloon, suction port for gastric contents, and an esophageal balloon.
- Minnesota tubes are the same as above, with the addition of an esophageal suction port and a larger gastric balloon volume.
Gastric balloons are filled with 250-500ml of air to ensure the balloon remains inflated and in the gastric body.
Esophageal balloons are only filled if the gastric balloon is not enough to stop bleeding. A manometer can be used to check pressures, which should remain between 25-45mmHg.
| Device | Ports | Gastric balloon | Esophageal balloon |
|---|---|---|---|
| Linton-Nachlas tube | 2 or 3 ports | 600 cc | — |
| Sengstaken-Blakemore tube | 3 ports | 250 cc | 30 - 45 mmHg |
| Minnesota tube | 4 ports | 500 cc | 30 - 45 mmHg |
Traction: These tubes must be placed in gentle traction, achieved by tying a bandage or string on the end of a port and connecting it to a 500ml or 1L bag of normal saline, which is suspended over an IV pole at the end of the bed. Achieving this level of traction during transport can be logistically difficult and needs to be planned and executed carefully and methodically to prevent any interruptions or inadvertent forceful pulling on the line.
Caution:
- Do not roll these patients side to side, as it may promote dislodging/migration of the tube
- Esophageal rupture may occur if the gastric balloon is inflated while in the esophagus or if the esophageal balloon has been inflated and necrosis occurs in surrounding tissue
- Patients will have increased vagal stimulation from pressure of tube; they are at risk for bradyarrhythmias for this reason
Technique:
- If not already done, the patient should be resting with head of bed at 30-45 degrees.
- Document which type of tube is being used and the depth at the teeth.
- Confirm depth with sending provider by marking at teeth. Confirm gastric balloon placement via x-ray.
- Document the status of each port (gastric balloon, gastric suction, esophageal balloon if present, esophageal suction); clamped, to suction, etc. Balloon ports should have 3-way stopcocks on them, turned off to the inflated balloon.
- Document the pressure in mmHg of gastric and esophageal balloons.
- Connect gastric suction port to low-intermittent suction to promote stomach emptying, prevent pressure build up which could elicit vomiting.
- Ensure the continuation of traction throughout transition to LifeLine equipment; may need to have one provider hold gentle traction during patient moves.
Safety equipment:
- Have scissors near bedside in emergency case of balloon migration and airway occlusion
- Keep two pairs of clamps at bedside in case of valve failure on balloon lumens
Manipulation of gastric or esophageal balloon is only to be done by a physician; uncontrolled release in pressure may result in catastrophic re-bleeding.
Radiology pearls:
Confirmation via Xray – the balloon should be under the diaphragm.
- Tube should follow esophageal tract, similar to naso & orogastric tubes
- Large balloon inflation should be fully below diaphragm, indicating it is in the gastric body and not in the esophagus (emergency)
Source page is a figure: three chest x-rays of tamponade tubes in place. One shows the tube following the esophageal tract with the balloon below the diaphragm; a second labeled "Like This." shows the large balloon inflated fully below the diaphragm; a third labeled "Not Like This." has arrows pointing to a balloon inflated in the chest, above the diaphragm.
Considerations for Transport:
- Upon arrival to the bedside, the esophageal tube is usually held in gentle traction by a 500 cc or 1000 cc bag of NS that is attached to the tube or one of its ports and dangled over an IV pole. It is very important to maintain this traction in transport to prevent migration of the esophageal tube. If Migration occurs, there may be catastrophic re-bleeding of varices.
- Using a bag of fluid for traction during transport can be difficult as it may bounce or swing excessively and cause migration of the tube.
- As an alternative to the IV bag, consider the following:
- Ensure with staff that the tube is in place and the current pressure of the balloons.
- Use a marker to mark the level of the balloon at the teeth.
- Place a second commercial ETT holder with the esophageal tube secured at the same depth at the teeth. Secure the Second ETT holder and ensure the depth is the same at the teeth, and document.
- It may be necessary for a teammate to maintain manual traction of the tube as the Second ETT holder is applied.
- The remaining external portion of the Esophageal tube may be taped to the forehead, making sure that there are no kinks in the tube and traction is maintained.
Source page is a figure: a photograph of an airway management trainer manikin with an endotracheal tube and a tamponade tube both secured at the mouth in one commercial tube holder, captioned "Picture 9: One Hollister is used for both ETT and Minnesota tube; an additional tube clamp is placed in series next to the ETT clamp."