1200

Mechanical Ventilation Strategies

Updated Updated November 2026. What changed: Protocol 1200 is rewritten and renamed from "Lung Protective Ventilation Strategies" to "Mechanical Ventilation Strategies": a general adult ventilator guideline targeting pPlat < 30, driving pressure < 15, Vt 6-8 mL/kg IBW and FiO2 <= 60%, with starting settings for ARDS/hypoxia, obstructive lung disease and severe metabolic acidosis plus high-pressure and auto-PEEP troubleshooting. The PEEP/FiO2 sliding scales, the height-based tidal volume tables and the recruitment-maneuver guidance are gone, and pressures are now printed in mmHg rather than cmH2O.
These protocols are here as an example, and are not to be used as an official resource or for patient care.

Purpose:

  • To establish a guideline for general ventilator management of critically ill and injured adult patients.

Key Performance Indicators:

  • pPlat < 30 mmHg
  • ΔP < 15 mmHg
  • Continuous waveform EtCO2 monitoring of all ventilated patients.
  • Continuous SpO2 monitoring of all ventilated patients.

Background:

Definition of terms:

  • Positive End Expiratory Pressure (PEEP): Pressure applied by ventilator during expiration.
  • Peak Inspiratory Pressure (Ppeak): Pairway resistance + Plateau Pressure.
  • Pairway Resistance: Pressure moving air between ventilator and alveoli.
    • Affected by: vent tubing, ETT, patient airways, etc.
  • Plateau Pressure (pPlat): Pressure distending alveoli at end-inspiration.
    • Affected by: lung compliance, extrinsic compression (e.g., abdominal distension, obesity, tension PTX).
    • pPlat = PEEP + Driving Pressure
  • Driving Pressure (ΔP): Change in pressure applied to the lung.
    ΔP = pPlat − PEEP
  • Plimit: Maximum pressure the ventilator will apply.
  • ΔP Control: Change in pressure applied by the ventilator in pressure control ventilation mode.
  • Auto-PEEP: Additional pressure above set PEEP remaining in lungs at end-expiration, often referred to as “air-trapping.”
  • Inspiratory: Expiratory (I: E) Ratio: Ratio of time spent in inspiration vs. expiration during one breath cycle.
  • Inspiratory Time (iTime): Time spent in inspiration during one breath cycle.
  • Tidal Volume (Vt): Amount of air (in mL) moved during a respiratory cycle.
  • Vt/IBW: Tidal volume (mL) per ideal body weight (kg).
  • Minute Ventilation (MV): Total volume of air entering or leaving lungs per minute (mL/min).
  • Waveform: Graphical representation of specific parameters over time (also referred to as scalars).
  • End-Tidal CO2 (EtCO2): Amount of exhaled CO2 measured at the end of expiration.
  • Continuous Waveform Capnography: Graphical representation of exhaled CO2 over time.

Hamilton T1 Terminology

Ventilator Modes:

  • APVcmv (Pressure-Regulated Volume Control):
    • Tidal volume is set; ventilator delivers a ΔPressure to meet that target without exceeding Plimit.
    • All breaths (patient or ventilator/time-initiated) receive the same calculated ΔPressure for the set iTime.
  • APVsimv (Synchronized Intermittent Mandatory Ventilation + Pressure-Regulated Volume Control):
    • Ventilator/time-initiated breaths receive the calculated ΔPressure for the set iTime.
    • Patient-initiated breaths receive the set ΔPressure support until flow drops below the set % of peak inspiratory flow (ETS), resulting in variable and typically shorter iTime.
  • PCV+ (Pressure Control Ventilation):
    • ΔPressure is set.
    • All breaths (patient or ventilator/time-initiated) receive the same ΔPressure for the set iTime.
  • PSIMV+ (Pressure Control + Synchronized IMV):
    • Ventilator/time-initiated breaths receive the set ΔPressure for the set iTime.
    • Patient-initiated breaths receive ΔPressure support until flow drops below the set % of peak inspiratory flow (ETS). iTime is variable and typically shorter than set iTime.

Limits:

  • Plimit: Maximum pressure the ventilator will apply.

Management Principles:

Monitoring of mechanically ventilated patients

  • All patients should be monitored via continuous waveform capnography and continuous pulse oximetry.
  • Ventilator pressure and flow waveforms should be monitored continuously during transport when feasible.

When to transition to mechanical ventilator

  • All patients with an advanced airway should be placed on a ventilator rather than bag ventilation, unless the equipment fails or the ventilator cannot maintain adequate oxygenation/ventilation.
  • Scene
  • Advanced airway in place prior to arrival: strongly consider bringing the ventilator to the patient before loading.
  • Advanced airway placed after arrival: consider bringing the ventilator to the patient if logistically feasible and/or if the patient is not being transported for a time-sensitive intervention.
  • Interfacility
  • Advanced airway in place prior to arrival: ventilator should be brought to the patient, and mechanical ventilation should be initiated before loading.
  • Advanced airway placed after arrival: strongly consider ventilator use prior to loading if logistically feasible and/or if not time-sensitive.

Goals of mechanical ventilation

Adequate Oxygenation

  • SaO2 (arterial oxygen saturation) is the main contributor to oxygen delivery, more so than PaO2.
  • SpO2 (pulse oximetry) should be used to assess oxygenation unless dyshemoglobinemia is suspected.
  • General goals:
  • SpO2 ≥ 90% (most patients).
  • SpO2 ≥ 88% (e.g., ARDS, COPD).
  • Avoid hyperoxia: Aim for SpO2 90–96% to reduce oxygen free radical damage.

Adequate Ventilation

  • Ideally assessed using blood gas (pH and pCO2).
  • EtCO2 may serve as a surrogate, but:
    • It underestimates pCO2 (~2–5 mmHg ideally).
    • More discrepancy in shock, PE, high FiO2, etc.
    • Most useful for trend monitoring.
  • General goals:
    • pCO2: 35–45 mmHg (EtCO2: 30–40 mmHg).
    • Metabolic acidosis may require lower pCO2.
    • Avoid pCO2 < 20–25 mmHg due to risk of cerebral vasoconstriction.

General ventilator strategy: Lung Protective Ventilation

  • Vt ≤ 6–8 mL/kg IBW
  • pPlat < 30 mmHg
  • ΔP < 15 mmHg
  • FiO2 ≤ 60%

Ventilator strategies for specific disease processes

Acute Respiratory Distress Syndrome (ARDS)/Hypoxia

  • Initial Ventilator Settings to Consider:
    • Mode: Pressure-regulated volume control (APVcmv)
    • Vt: 6 mL/kg IBW
    • RR: 16–18 breaths/min
    • PEEP: 8 mmHg+
    • FiO2: ≤ 60%
  • Specific Goals to Consider:
    • SpO2 ≥ 88%
    • Permissive hypercarbia with pH ≥ 7.25
  • If PPlat ≥ 30 mmHg, consider:
    • Ensure adequate sedation.
    • Assess for Auto-PEEP (see below).
    • Assess for abdominal distension (see Pressure Limitation/High Pressure Alarm below).
    • Lower Vt by 1 mL/kg IBW and reassess
  • If Driving Pressure (ΔP) > 15 mmHg, consider:
    • Increase PEEP by 2 and reassess ΔP
      • If ΔP decreases → PEEP was beneficial.
      • If ΔP increases → PEEP may be causing over distension; decrease to previous level.
    • Trial same interventions for elevated PPlat.
  • Optimize iTime / Mean Airway Pressure
    • Mean Airway Pressure =
      [(iTime × Inspiratory Pressure) + (eTime × Expiratory Pressure)] / (iTime + eTime)
      • A marker of alveolar recruitment.
    • Goal: inspiratory flow waveform returns to baseline as ventilator cycles into exhalation.

Source page is a figure: ventilator flow (upper) and pressure (lower) waveforms with an arrow marking the inspiratory flow reaching baseline just as the ventilator cycles into exhalation. Labels printed on it: PEEP = 12, PIP= 26, iTime = 6, eTime = 6, MAP = 19.

  • If not returning to baseline, consider increasing iTime.

Source page is a figure: ventilator flow (upper) and pressure (lower) waveforms with an arrow marking the inspiratory flow still above baseline when the ventilator cycles into exhalation. Labels printed on it: PEEP = 12, PIP= 26, iTime = 4, eTime = 8, MAP = 17.

  • If returning to baseline before exhalation: consider decreasing iTime.

Source page is a figure: ventilator flow (upper) and pressure (lower) waveforms with an arrow marking the inspiratory flow returning to baseline well before the ventilator cycles into exhalation. Labels printed on it: PEEP = 12, PIP= 26, iTime = 8, eTime = 4, MAP = 21.

Refractory Hypoxia:

  • Consider paralysis
    • CAUTION: ensure post-paralysis MV is similar to pre-paralysis MV to prevent hypercarbia.
  • Consider inhaled pulmonary vasodilator if sending can initiate (e.g., epoprostenol, nitric oxide) – see Epoprostenol.
  • Consider prone positioning.

Obstructive Lung Disease:

  • Initial ventilator settings to consider:
    • Vt: 6–8 mL/kg IBW
    • RR: 12 (can increase if no significant Auto-PEEP)
    • I:E ratio: 1:4+
    • FiO2: ≤ 60%
  • Specific goals to consider:
    • SpO2 ≥ 88%
    • Permissive hypercarbia with pH ≥ 7.25
  • May need to modify Plimit or Pressure Alarm:
    • Why:
      • Bronchoconstriction causes high peak pressure, but PPlat (alveolar pressure) may be normal.
      • Once Plimit is reached, the vent stops delivering volume → lower delivered Vt.
      • Once Pressure Alarm is reached, the vent stops delivering inspiratory pressure → shorter iTime and/or lower delivered Vt.
    • How to decide if it's safe to increase:
      • Assess ΔP and PPlat.
      • If ΔP < 15 mmHg and PPlat < 30 mmHg → alveoli not being damaged.
        → Increase Plimit to allow delivery of Vt
      • Reassess ΔP and PPlat to ensure alveoli remain protected.
  • Monitor for Auto-PEEP (see below)

Severe Metabolic Acidosis:

  • Initial ventilator settings to consider:
    • Mode: Pressure control (PCV)
    • ΔP Control: 15 mmHg
    • RR: 26+
    • I:E ratio: ≤ 1:2
    • FiO2: ≤ 60%
  • Specific goals to consider:
    • pCO2 ≥ 20–25 mmHg
  • Patients may take very large tidal volumes (>8–10 mL/kg IBW) due to high respiratory drive.
    • Assess ΔP and PPlat:
    • If ΔP < 15 mmHg and PPlat < 30 mmHg → alveoli are not being damaged.
    • If ΔP > 15 mmHg or PPlat ≥ 30 mmHg → decrease ΔP control and reassess.

Troubleshooting

Pressure Limitation / High Pressure Alarm:

  • Definitions:
    • Pressure Limitation: Measured inspiratory pressure exceeds Plimit.
    • High Pressure Alarm: Measured inspiratory pressure exceeds alarm limit.
  • Ventilator Response:
    • Pressure Limitation: stops delivering volume → Vt lower than set.
    • High Pressure Alarm: terminates inspiratory phase → shorter iTime/lower Vt.
  • Step 1: ensure adequate oxygenation/ventilation.
    • Assess patient SpO2/EtCO2 and MV.
    • If unable to oxygenate or ventilate:
      • Disconnect and bag.
      • Temporarily increase FiO2.
      • Temporarily increase Plimit or Pressure alarm.
  • Step 2: Determine Cause → Treatment.
    • Coughing/Dyssynchrony: Increase sedation
    • High ΔP (> 15 mmHg) or PPlat (≥ 30 mmHg):
      • Assess for Auto-PEEP (see below).
      • Acute derecruitment → Re-recruit, return to lung-protective strategy.
        • May need to lower Vt, tolerate hypercarbia.
        • Note: Sudden rise in ΔP/PPlat unlikely due to worsening ARDS.
      • PTX → Decompress
      • Mainstem intubation → Withdraw ETT
      • Abdominal distension → OG tube, raise HOB, increase Plimit/alarm (see Step 3)
    • Normal ΔP (< 15 mmHg) and PPlat (< 30 mmHg):
      → High Pairway resistance (work from ventilator out to find the obstruction).
      • Vent Tubing: Kinked/fluid-filled → fix it, adjust Plimit/alarm.
      • ETT: If suction catheter passes freely → not obstructed
        • Kinked → fix it.
        • Patient biting → sedation, adjust bite block.
        • Secretions → suction.
      • Patient Airways:
        • Bronchoconstriction → bronchodilator, adjust Plimit/alarm
        • High RR or Vt → adjust Plimit/alarm
        • Other causes → adjust Plimit/alarm
  • Step 3: Increase Plimit/Pressure Alarm
    • If ΔP < 15 mmHg and PPlat < 30 mmHg → safe to increase alarm limits.
    • Reassess after changes.

Auto-PEEP / High PEEP Alarm:

  • Definition:
    • High PEEP Alarm: Measured expiratory pressure is ≥ 5 mmHg above set PEEP
  • Assess Auto-PEEP.
    • Auto-PEEP value:
      • > 0 → Some air-trapping
      • > ~3–5 → Likely clinically significant
    • Assess flow waveform:
      • Normal flow waveform: returns to baseline prior to transition to inspiration (see arrow).

Source page is a figure: ventilator waveforms labeled Pressure (upper) and Flow (lower); an arrow points to the expiratory flow sitting back at the baseline before the next inspiration begins.

  • Auto-PEEP on flow waveform: not returning to baseline before transition to inspiration (see arrow).

Source page is a figure: ventilator waveforms labeled Pressure (upper) and Flow (lower); an arrow points to the expiratory flow still below the baseline when the next inspiration begins.

  • To fix Auto-PEEP:
    • Decrease Vt by 1 mL/kg IBW
    • Decrease RR
    • Decrease iTime → increase I:E ratio
    • Note: Fixing Auto-PEEP often results in hypercarbia. For most patients, permissive hypercarbia is preferable to the risks of auto-PEEP.

References

  • Amato et. al. Driving Pressure. 2015
  • Aoyama H, Pettenuzzo T, Aoyama K, Pinto R, Englesakis M, Fan E. Association of Driving Pressure With Mortality Among Ventilated Patients With Acute Respiratory Distress Syndrome: A Systematic Review and Meta-Analysis*. Crit Care Med. 2018;46(2):300-306. doi:10.1097/CCM.0000000000002838
  • Demoule et. al. How to Ventilate Obstructive and Asthmatic Patients. ICM 2020
  • Grasselli et. al. ESICM Guidelines on acute respiratory distress syndrome: definition, phenotyping, and respiratory support strategies. Intensive Care Medicine. 49:727-759, 2023
  • Fan et. al. An Official American Thoracic Society/European Society of Intensive Care Medicine/Society of Critical Care Medicine Clinical Practice Guideline: Mechanical Ventilation in Adult Patients with Acute Respiratory Distress Syndrome. Am J Respir Crit Care Med Vol 195, Iss 9, pp 1253–1263, May 1, 2017
  • Qadir, et.al. An Update on Management of Adult Patients with Acute Respiratory Distress Syndrome: An Official American Thoracic Society Clinical Practice Guideline. Am J Respir Crit Care Med. Nov 30, 2023

Appendix or links to Supplemental Aids

  • EMCCT (Adult) Pocket Reference: ABG, Parameters, RASS, Respiratory/Ventilator (ARDS net, NIPPV helpful hints, in-line nebulizer set-up, ventilator troubleshooting, DOPES)