Oxygen
These protocols are here as an example, and are not to be used as an official resource or for patient care.
Description: Oxygen added to the inspired air increases the amount in the blood, increasing the amount delivered to the tissue. Tissue hypoxia causes cell damage and death. Breathing, in most people, is regulated by slight changes in the acid-base balance and CO2 levels.
Indications:
- Suspected hypoxemia or respiratory distress from any cause
- Acute chest or abdominal pain
- Hypotension/shock states from any cause
- Trauma
- Suspected carbon monoxide poisoning
- Obstetrical complications, childbirth
Precautions:
- If the patient breathes ineffectively, the treatment of choice is assisted ventilation, not just oxygen.
- When pulse oximetry is available, titrate SpO2 to ≥ 90%. This may take some time.
- Do not withhold oxygen from a COPD (Chronic Obstructive Pulmonary Disease) patient out of concerns for loss of hypoxic respiratory drive. This is never a concern in the prehospital setting with short transport times
- High oxygen saturations will cause ductus arteriosus closure in newborns which may cause decompensation in patients with ductal dependent lesions.
| Flow | LPM Dosage | Indications |
|---|---|---|
| Low Flow | 1-2 LPM | Minor medical / trauma |
| Moderate Flow | 3-9 LPM | Moderate medical / trauma |
| High Flow | 10-15 LPM | Severe medical / trauma |
Special notes:
- If the patient warrants humidified oxygen, use a single patient use device.
- Adequate oxygenation is assessed clinically and with the SpO2 while adequate ventilation is assessed clinically and with waveform capnography.
| Method | Flow Rate | Oxygen Inspired Air (approximate) |
|---|---|---|
| Room Air | 21% | |
| Nasal Cannula | 1 LPM | 24% |
| Nasal Cannula | 2 LPM | 28% |
| Nasal Cannula | 6 LPM | 44% |
| Simple Face Mask | 8 - 10 LPM | 40-60% |
| Non-rebreather Mask | 10 LPM | 90% |
| Bag/Valve/Mask (BVM) | Room Air | 21% |
| Bag/Valve/Mask (BVM) | 12 LPM | 40% |
| Bag/Valve/Mask with Reservoir | 10-15 LPM | 90-100% |
| Oxygen-powered breathing device | Regulated via device | 100% |